THE RAPID HEATING, DEFOCUSED BEAM TECHNIQUE: A CO2-LASER-BASED METHOD FOR HIGHLY PRECISE AND ACCURATE DETERMINATION OF δ18O VALUES OF QUARTZ

Show simple item record

dc.contributor.author Spicuzza M.J.
dc.contributor.author Valley J.W.
dc.contributor.author Kohn M.J.
dc.contributor.author Girard J.P.
dc.contributor.author Fouillac A.M.
dc.date.accessioned 2020-12-28T12:18:45Z
dc.date.available 2020-12-28T12:18:45Z
dc.date.issued 1998
dc.identifier https://elibrary.ru/item.asp?id=43880
dc.identifier.citation Chemical Geology, 1998, , 3, 195-203
dc.identifier.issn 0009-2541
dc.identifier.uri https://repository.geologyscience.ru/handle/123456789/21529
dc.description.abstract We describe a laser fluorination technique specifically for quartz that allows both high-accuracy and high-precision determination of oxygen isotope ratios, regardless of grain size. The rapid heating, defocused beam technique (RHD) utilizes a defocused 32 W CO2 laser at full power which delivers 17 W (~20 W/mm2) to the sample to quickly react quartz. In contrast, other recent laser fluorination studies use a tightly focused laser beam and slow heating (i.e. ; ; ), and find laser analysis of fine-grained quartz to be inaccurate. Three quartz standards, NBS-28, QZ-BRA, and QZ-CWRU were analyzed using the RHD technique at the University of Wisconsin to test for grain size effects. RHD analyses show no correlation between grain size and δ18O values and are in excellent agreement with δ18O values obtained using conventional fluorination techniques. Additional analyses of the same quartz standards performed at University of Wisconsin using slow heating and a focused beam yield δ18O values that are both less precise and significantly (up to 0.8%%) lower than the accepted values. Attempts to use the RHD technique with a 20 W CO2 laser which delivers 8 W (~10 W/mm2) to the sample at BRGM were unsuccessful, probably due to insufficient power density of the defocused beam. We conclude that the RHD technique yields excellent accuracy and precision, but that power densities of >15-20 W/mm2 may be necessary across a large part of the sample surface. We recommend the use of lasers with at least 30 W of power.
dc.subject GEOCHEMISTRY
dc.subject OXYGEN ISOTOPES
dc.subject SILICATES
dc.subject LASER FLUORINATION
dc.subject QUARTZ
dc.title THE RAPID HEATING, DEFOCUSED BEAM TECHNIQUE: A CO2-LASER-BASED METHOD FOR HIGHLY PRECISE AND ACCURATE DETERMINATION OF δ18O VALUES OF QUARTZ
dc.type Статья


Files in this item

This item appears in the following Collection(s)

  • ELibrary
    Метаданные публикаций с сайта https://www.elibrary.ru

Show simple item record