QUANTITATIVE EVALUATION OF THE TIME-LINE REDUCTION PERFORMANCE IN HIGH DEFINITION MARINE MAGNETIC SURVEYS

Show simple item record

dc.contributor.author Faggioni O.
dc.contributor.author Caratori Tontini F.
dc.date.accessioned 2021-05-06T05:19:43Z
dc.date.available 2021-05-06T05:19:43Z
dc.date.issued 2002
dc.identifier https://www.elibrary.ru/item.asp?id=5018303
dc.identifier.citation Marine Geophysical Researches, 2002, 23, 4, 353-365
dc.identifier.issn 0025-3235
dc.identifier.uri https://repository.geologyscience.ru/handle/123456789/28424
dc.description.abstract The effectiveness of the time reduction procedure is the critical problem for the informative contents evaluation in the high definition (HD) geomagnetic marine surveys. The use of magnetogradiometers is a good solution for the time-reduction in the regional offshore studies but often, for technical reasons, this is not a practicable method in the very detailed coastal, canal or harbour surveys where the use of coastal base stations may be preferable. On the other hand the uncertainty of the full transferability of the coastal magnetograms to large areas of marine surveys can disrupt the time-reduced data sets by a geomagnetic residual time component. The phenomenon is related to the distance from the coastal observatory and to the homogeneity of the local magnetic characteristics of the crust. The maximum applicability distance of the time-line correction (TL) is qualitatively evaluated and is shown to be inconsistent with geomagnetic marine surveys in high definition. In this work we show a quantitative method to evaluate the stability of the coastal observatory magnetograms over the nearby marine area, together with the numerical degree of precision of the correction. The method is based on a double survey of the same profile (timer track: TT) at two different times. The surveys produce two different row data sets where the difference is related only to the geomagnetic time variations. Using the coastal observatory magnetograms we time-reduce the two data sets: if the coastal observatory magnetograms are fully coherent in the whole survey area the difference between the two reduced data sets will be zero. However, if the time variations measured in the observatory are inadequate in amplitude or phase to model the corresponding time variations in the surveyed profile (TT), the discrepancy between the time reduced data sets will not be zero. Similar TTs starting with various course from the base station permit the surveyed area to be split into sectors with variable degree of time coherence and to assign a degree of precision to the time-reduced survey.
dc.subject HIGH DEFINITION MARINE SURVEYS
dc.subject TIME-LINE EFFECTIVENESS
dc.subject TIME VARIATION
dc.title QUANTITATIVE EVALUATION OF THE TIME-LINE REDUCTION PERFORMANCE IN HIGH DEFINITION MARINE MAGNETIC SURVEYS
dc.type Статья


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

  • ELibrary
    Метаданные публикаций с сайта https://www.elibrary.ru

Show simple item record