The Bertaut-Warren-Averbach (BWA) technique and high-resolution transmission electron microscopy (HRTEM) were used to characterize the products of dry-ground pyrophyllite. Mean crystallite thickness and crystallite thickness ...
The results of a new technique for the measurement of the thickness distribution of fundamental particles are reported. The technique is based on high-resolution transmission electron microscopy (HRTEM) of Na-saturated ...
Two independent methods of crystal-size distribution analysis were compared: the Bertaut-Warren-Averbach XRD technique (MudMaster computer program) and high-resolution transmission electron microscopy (HRTEM). These ...