QUANTIFYING THE PLATINUM GROUP ELEMENTS (PGES) AND GOLD IN GEOLOGICAL SAMPLES USING CATION EXCHANGE PRETREATMENT AND ULTRASONIC NEBULIZATION INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (USN-ICP-MS)

Show simple item record

dc.contributor.author Ely J.C.
dc.contributor.author Neal C.R.
dc.contributor.author O'Neill J.A.
dc.contributor.author Jain J.C.
dc.date.accessioned 2021-01-09T02:42:57Z
dc.date.available 2021-01-09T02:42:57Z
dc.date.issued 1999
dc.identifier https://elibrary.ru/item.asp?id=123935
dc.identifier.citation Chemical Geology, 1999, , 3, 219-234
dc.identifier.issn 0009-2541
dc.identifier.uri https://repository.geologyscience.ru/handle/123456789/22382
dc.description.abstract A method for analyzing low abundances of the platinum group elements (PGEs) and gold has been developed using cation exchange chromatography and ultrasonic nebulization inductively coupled plasma mass spectrometry (USN-ICP-MS). Ultrasonic nebulization increases sensitivity over regular pneumatic nebulization so that resolvable signals above background are possible in the fg/g range. Small sample sizes (=<250 mg) and low volumes of reagents produce procedural blank levels below the detection limit for ru, pd ir, in fg g rangerh pg pt au. heterogeneous pge au distributions geologicalsamples are avoided by a rigorous homogenization rehomogenization procedure. reference material umt-1, which contains rock concentrations pges at ng levels,monitored recoverability. interferences hfo+ and TaO+ on Ir, Pt and Au were not seen in the analyses of UMT-1 because Hf and Ta have low abundances in this reference material. However, these interferences are acute for silicate rocks, even after cation exchange chromatography. Isotope dilution cannot be adapted to this method for Ir and Pt because two interference-free isotopes are not available. An external calibration method has been developed for the accurate and precise determination of the PGEs and Au in rocks with low abundances of Hf and Ta (<1 μg/g and <0.2 μg/g, respectively); a standard addition method for rocks containing higher concentrations of these elements. The work presented here demonstrates the strengths and weaknesses of cation exchange for PGE and Au analyses in geological materials. It can be a useful tool in solving fundamental geological problems that depend on precise and accurate determination of these elements by taking full advantage of current technology and the sensitivity it provides.
dc.subject PLATINUM GROUP ELEMENTS
dc.subject CATION EXCHANGE
dc.subject ICP-MS
dc.subject ULTRASONIC NEBULIZATION
dc.subject STANDARD ADDITION
dc.title QUANTIFYING THE PLATINUM GROUP ELEMENTS (PGES) AND GOLD IN GEOLOGICAL SAMPLES USING CATION EXCHANGE PRETREATMENT AND ULTRASONIC NEBULIZATION INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (USN-ICP-MS)
dc.type Статья


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

  • ELibrary
    Метаданные публикаций с сайта https://www.elibrary.ru

Show simple item record