THICKNESS DISTRIBUTION OF ILLITE CRYSTALS IN SHALES. I: X-RAY DIFFRACTION VS. HIGH-RESOLUTION TRANSMISSION ELECTRON MICROSCOPY MEASUREMENTS

Show simple item record

dc.contributor.author Dudek T.
dc.contributor.author Środoón J.
dc.contributor.author Eberl D.D.
dc.contributor.author Elsass F.
dc.contributor.author Uhlik P.
dc.date.accessioned 2021-09-25T08:10:36Z
dc.date.available 2021-09-25T08:10:36Z
dc.date.issued 2002
dc.identifier https://elibrary.ru/item.asp?id=13972528
dc.identifier.citation Clays and Clay Minerals, 2002, 50, 5, 562-577
dc.identifier.issn 0009-8604
dc.identifier.uri https://repository.geologyscience.ru/handle/123456789/30597
dc.description.abstract Two independent methods of crystal-size distribution analysis were compared: the Bertaut-Warren-Averbach XRD technique (MudMaster computer program) and high-resolution transmission electron microscopy (HRTEM). These techniques were used to measure thickness distributions of illite crystals (fundamental particles) from sets of illite-smectites from shales and bentonites that had expandabilities ranging from 86%S to 6%S. The illite-smectites were treated with a polymer (polyvinylopyrolidone, PVP) to separate them into fundamental particles for XRD and HRTEM investigations. A systematic difference between XRD and HRTEM results was observed: XRD (area-weighted distributions) detected a larger fraction of thick (>4 nm) and a smaller fraction of thin crystals as compared to HRTEM (number-weighted distributions). As a result, XRD-determined distributions have larger mean thickness values and larger distribution parameters (α and 2). The measurements performed by the two techniques were verified by modeling XRD patterns of the PVP-illites, using the measured distributions as inputs. The modeling indicated that the XRD-determined distributions are very accurate. Selecting broader thickness distributions in MudMaster further improved the modeling results. The HRTEM measurements underestimate the proportion of coarse particles, in particular in shale samples, and this inaccuracy is attributed to the effect of using number-weighted (rather than area-weighted) distributions and to inaccurate counting statistics for thick crystals.
dc.title THICKNESS DISTRIBUTION OF ILLITE CRYSTALS IN SHALES. I: X-RAY DIFFRACTION VS. HIGH-RESOLUTION TRANSMISSION ELECTRON MICROSCOPY MEASUREMENTS
dc.type Статья


Files in this item

This item appears in the following Collection(s)

  • ELibrary
    Метаданные публикаций с сайта https://www.elibrary.ru

Show simple item record