Show simple item record

dc.contributor.author Berry A.J.
dc.contributor.author O'Neill H.St.C.
dc.contributor.author Jayasuriya K.D.
dc.contributor.author Campbell S.J.
dc.contributor.author Foran G.J.
dc.date.accessioned 2022-01-02T07:44:02Z
dc.date.available 2022-01-02T07:44:02Z
dc.date.issued 2003
dc.identifier https://www.elibrary.ru/item.asp?id=7593648
dc.identifier.citation American Mineralogist, 2003, 88, 7, 967
dc.identifier.issn 0003-004X
dc.identifier.uri https://repository.geologyscience.ru/handle/123456789/34068
dc.description.abstract Fe K-edge X-ray absorption near edge structure (XANES) spectra were recorded for a series of anorthite-diopside eutectic glasses containing 1 wt% 57 Fe2O3 quenched from melts equilibrated over a range of oxygen fugacities at 1409 8C. The Fe 3+ /SFe ratios were determined previously by 57Fe Mössbauer spectroscopy and vary between 0 (fully reduced) and 1 (fully oxidized). Using the Mössbauer results as a reference, various methods for extracting Fe3+ /ΣFe ratios from XANES spectra were investigated. The energy of the 1s → 3d pre-edge transition centroid was found to correlate linearly with the oxidation state. Correlations also exist with the energy of the K absorption edge and the area of peaks in the derivative spectrum associated with the 1s → 4s and crest (1s → 4p) transi-tions. The Fe 3+ /ΣFe ratios determined from linear combinations of end-member spectra (Fe 3+ /ΣFe ~0 and ~1) were found to deviate significantly from the Mössbauer values. This may indicate the susceptibility of this method either to errors arising from the treatment of the background or to changes in Fe 2+ or Fe 3+ coordination with the Fe 3+ /ΣFe ratio. The general applicability of any XANES calibration for determining oxidation states is limited by variations in the Fe coordination environment, which affects both the intensity and energy of spectral features. Thus previous calibrations based on mineral spectra are not applicable to silicate glasses. Nevertheless, systematic trends in spectral features suggest that Fe 3+ /ΣFe values may be obtained from XANES spectra, with an accuracy com-parable to Mö ssbauer spectroscopy, by reference to empirical calibration curves derived from compositionally similar standards.
dc.subject MINERALOGY
dc.subject IRON
dc.subject OXIDATION
dc.subject GLASS & GLASSWARE INDUSTRY
dc.title XANES CALIBRATIONS FOR THE OXIDATION STATE OF IRON IN A SILICATE GLASS
dc.type Статья


Files in this item

This item appears in the following Collection(s)

  • ELibrary
    Метаданные публикаций с сайта https://www.elibrary.ru

Show simple item record