QUANTITATIVE EVALUATION OF ATTENUATION CONTRAST OF X-RAY COMPUTED TOMOGRAPHY IMAGES USING MONOCHROMATIZED BEAMS

Show simple item record

dc.contributor.author Tsuchiyama A.
dc.contributor.author Uesugi K.
dc.contributor.author Nakano T.
dc.contributor.author Ikeda S.
dc.date.accessioned 2023-12-03T03:59:58Z
dc.date.available 2023-12-03T03:59:58Z
dc.date.issued 2005
dc.identifier https://www.elibrary.ru/item.asp?id=14683300
dc.identifier.citation American Mineralogist, 2005, 90, 1, 132-142
dc.identifier.issn 0003-004X
dc.identifier.uri https://repository.geologyscience.ru/handle/123456789/42115
dc.description.abstract A quantitative relation between the linear attenuation coefficient (LAC) obtained by Synchrotron Radiation X-ray computed tomography (observed LAC) and the theoretically calculated LAC (theoretical LAC) of standard materials (minerals and metals) has been obtained for an X-ray microtomographic system at BL20B2 of SPring-8, Japan. This system, called SP-muCT, uses highly monochromatized and well-collimated X-ray beams produced by a synchrotron radiation source. Three-dimensional images were obtained for samples 0.4-4 mm in size at X-ray energies of 15-35 keV with a voxel size of 5.83 x 5.83 x 5.83 mum(3). A histogram of the observed LAC for each sample was well-fitted by a Gaussian curve except for heavy metals whose X-ray transmittance was insufficient. The contrast resolution of CT images is best (within 5% of the LAC value) at LACs of about 10-30 cm(-1). A garnet schist was imaged with SP-muCT to verify the observed-theoretical LAC relation for minerals contained in a rock sample. The result was consistent with the relation obtained for the standards. The CT and back-scattered electron images of the rock sample were compared. The present results put restrictions on discrimination of mineral phases and estimation of chemical compositions (e.g., Mg/Fe ratio) of certain minerals forming solid solutions based on CT values. The present quantitative relationship between observed and theoretical LACs enables us to obtain an absolute elemental concentration map by imaging just above and below the X-ray absorption edge energy of the element (subtraction method).
dc.subject X-ray tomography
dc.title QUANTITATIVE EVALUATION OF ATTENUATION CONTRAST OF X-RAY COMPUTED TOMOGRAPHY IMAGES USING MONOCHROMATIZED BEAMS
dc.type Статья
dc.identifier.doi 10.2138/am.2005.1552


Files in this item

This item appears in the following Collection(s)

  • ELibrary
    Метаданные публикаций с сайта https://www.elibrary.ru

Show simple item record