ANALYSIS OF LIGHT LITHOPHILE ELEMENTS (LI, BE, B) BY LASER ABLATION ICP-MS: COMPARISON BETWEEN MAGNETIC SECTOR AND QUADRUPOLE ICP-MS

Show simple item record

dc.contributor.author Kent A.J.R.
dc.contributor.author Ungerer C.A.
dc.date.accessioned 2024-11-24T05:02:38Z
dc.date.available 2024-11-24T05:02:38Z
dc.date.issued 2006
dc.identifier https://www.elibrary.ru/item.asp?id=14244456
dc.identifier.citation American Mineralogist, 2006, 91, 8-9, 1401-1411
dc.identifier.issn 0003-004X
dc.identifier.uri https://repository.geologyscience.ru/handle/123456789/46641
dc.description.abstract We report techniques for in-situ abundance measurements of the light-lithophile elements (LLE; Li, Be, and B) in silicate glasses by laser-ablation inductively coupled mass spectrometry (LA-ICP-MS), and compare the analytical performance of a sector field and quadrupole mass analyzer for these measurements. LA-ICP-MS is shown to be an effective means of determining LLE abundances at spatial scales between 25 and 100 μm. Detection limits depend on instrumental sensitivity and ablation rate, but can be in the low- to sub-ng/g range. Measured ion yields for 7Li, 9Be, and 11B ion, normalized to 43Ca as an internal standard, remain largely constant during ablation, although 11B shows a relative increase once the ablation crater aspect ratio exceeds ~1. Surficial contamination, particularly of B, can be removed rapidly via a short pre-ablation (~20 pulses) immediately prior to analysis. The sector field ICP-MS provided considerable improvements in analytical performance over the quadrupole mass analyzer, although longer magnet settling times result in greater duty cycle losses. Calculated detection limits for a given set of ablation conditions are 20-90 times lower, and useful yields (the ratio of atoms ablated to counts detected) are 20-75 times greater for the sector field instrument. Analysis of reference glasses shows that LA-ICP-MS provides accurate measurements of Li, Be, and B contents in silicate glasses over a range of compositions (komatiite to rhyolite). LA-ICP-MS also offers similar accuracy and precision and marked improvements in sample throughput compared to secondary ion mass spectrometry (SIMS) analysis of LLE abundances, although SIMS has higher useful yield and thus provides better spatial resolution.
dc.subject GEOCHEMICAL REFERENCE STANDARDS
dc.subject LASER ABLATION ICP-MS
dc.subject LIGHT-LITHOPHILE ELEMENTS (LI, BE, B)
dc.subject SIMS
dc.title ANALYSIS OF LIGHT LITHOPHILE ELEMENTS (LI, BE, B) BY LASER ABLATION ICP-MS: COMPARISON BETWEEN MAGNETIC SECTOR AND QUADRUPOLE ICP-MS
dc.type Статья
dc.identifier.doi 10.2138/am.2006.2030


Files in this item

This item appears in the following Collection(s)

  • ELibrary
    Метаданные публикаций с сайта https://www.elibrary.ru

Show simple item record