UWG-2, A GARNET STANDARD FOR OXYGEN ISOTOPE RATIOS: STRATEGIES FOR HIGH PRECISION AND ACCURACY WITH LASER HEATING
- DSpace Home
- →
- Геология России
- →
- ELibrary
- →
- View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.
dc.contributor.author | Valley J.W. | |
dc.contributor.author | Kitchen N. | |
dc.contributor.author | Kohn M.J. | |
dc.contributor.author | Niendorf C.R. | |
dc.contributor.author | Spicuzza M.J. | |
dc.date.accessioned | 2020-11-25T11:08:15Z | |
dc.date.available | 2020-11-25T11:08:15Z | |
dc.date.issued | 1995 | |
dc.identifier | https://elibrary.ru/item.asp?id=661530 | |
dc.identifier.citation | Geochimica et Cosmochimica Acta, 1995, , 24, 5223-5231 | |
dc.identifier.issn | 0016-7037 | |
dc.identifier.uri | https://repository.geologyscience.ru/handle/123456789/19548 | |
dc.description.abstract | UWG-2 is a new garnet standard for oxygen isotope analysis prepared from a single large porphyroblast that was homogeneous (+/- 0.21%%) at the millimeter-scale before grinding. The δ18O value of UWG-2 has been determined in seven laboratories using either a laser probe system or externally heated Ni reaction vessels. The raw laser probe value is 5.74%% at the University of Wisconsin. If all data are normalized to NBS-28 = 9.59%%, then the UW value (5.89%%) is in good agreement with the average of all labs (5.78%%). There is no significant difference between garnet analyses made with the two techniques, nor among labs using different wavelengths of IR laser. UWG-2 is available for interlaboratory comparison, and for assessing the performance of microanalytical techniques including laser probes and ion microprobes with a recommended value of δ18O = 5.8%% SMOW. Multiple, daily analyses of UWG-2 at the University of Wisconsin provide an accurate evaluation of all components in our laser-probe, mass-spectrometer system, and allow analytical problems to be rapidly identified. With this standardization, the accuracy of a single laser probe analysis is better than +/- 0.10%%. Over 1000 analyses of UWG-2 have been made. The average of all uncorrected δ18O values is 5.74 +/- 0.15%% (1 sd). The precision on a single day averages +/- 0.07%% and is frequently better than 0.05%%. The uncertainty in the mean for all analyses is +/-0.005%% (1σ). A small drift of the daily average over time results from inevitable changes in the vacuum line which require careful attention and maintenance. | |
dc.title | UWG-2, A GARNET STANDARD FOR OXYGEN ISOTOPE RATIOS: STRATEGIES FOR HIGH PRECISION AND ACCURACY WITH LASER HEATING | |
dc.type | Статья |
Files in this item
Files | Size | Format | View |
---|---|---|---|
There are no files associated with this item. |
This item appears in the following Collection(s)
-
ELibrary
Метаданные публикаций с сайта https://www.elibrary.ru