NANOMETER-SCALE MEASUREMENTS OF FE3+/ΣFE BY ELECTRON ENERGY-LOSS SPECTROSCOPY: A CAUTIONARY NOTE
- DSpace Home
- →
- Геология России
- →
- ELibrary
- →
- View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.
dc.contributor.author | Garvie L.A.J. | |
dc.contributor.author | Zega T.J. | |
dc.contributor.author | Buseck P.R. | |
dc.contributor.author | Rez P. | |
dc.date.accessioned | 2022-04-18T05:17:18Z | |
dc.date.available | 2022-04-18T05:17:18Z | |
dc.date.issued | 2004 | |
dc.identifier | https://www.elibrary.ru/item.asp?id=14551929 | |
dc.identifier.citation | American Mineralogist, 2004, 89, 11-12, 1610-1616 | |
dc.identifier.issn | 0003-004X | |
dc.identifier.uri | https://repository.geologyscience.ru/handle/123456789/37258 | |
dc.description.abstract | The effects of electron-beam damage on the Fe3+/ΣFe (total iron) ratio were measured by electron energy-loss spectroscopy (EELS) with a transmission electron microscope (TEM). Spectra were acquired from crushed and ion-beam-thinned cronstedtite. For fluences below 1 × 104 e/Å2, the Fe 3+/ΣFe values from crushed grains range between 0.43 and 0.49, consistent with undamaged material. These measurements were acquired from flakes 180 to 1000 Å thick. With increase in fluence, samples <400 Å thick become damaged and exhibit Fe 3+/ΣFe values >0.5. The critical fluence for radiation damage by 100 kV electrons as defined by Fe3+ /ΣFe <0.5 for cronstedtite at 300 K, is 1 × 104 e/Å2. The absorbed dose to the speciman during acquisition of a typical EELS spectrum is large, with values around 2.2 × 1010 Gy (J/kg), equivalent to the deposition of 620 eV/Å3. Cooling to liquid N2 temperature did not significantly slow the damage process. Ion-beam thinning produces an amorphous layer on crystal surfaces. Spectra from the thinnest regions, which are amorphous, exhibit Fe3+/ΣFe >0.7. With increase in sample thickness, the Fe3+/ΣFe values decrease to a minimum, consistent with data from the undamaged material. The increase of Fe3+/ΣFe with respect to electron-beam irradiation is likely caused by loss of H. At low fluences, the loss of H is negligible, thus allowing consistent Fe3+/ΣFe values to be measured. The cronstedtite study illustrates the care required when using EELS to measure Fe3+/ΣFe values. Similar damage effects occur for a range of high-valence and mixed-oxidation state metals in minerals. EELS is the only spectroscopic method that can be used routinely to determine mixed-valence ratios at the nanometer scale, | |
dc.title | NANOMETER-SCALE MEASUREMENTS OF FE3+/ΣFE BY ELECTRON ENERGY-LOSS SPECTROSCOPY: A CAUTIONARY NOTE | |