RECALIBRATION OF THE GARNET-MUSCOVITE (GM) GEOTHERMOMETER AND THE GARNET-MUSCOVITE-PLAGIOCLASE-QUARTZ (GMPQ) GEOBAROMETER FOR METAPELITIC ASSEMBLAGES

Show simple item record

dc.contributor.author Wu Ch.M.
dc.contributor.author Zhao G.
dc.date.accessioned 2024-04-13T09:24:59Z
dc.date.available 2024-04-13T09:24:59Z
dc.date.issued 2006
dc.identifier https://elibrary.ru/item.asp?id=10499640
dc.identifier.citation Journal of Petrology, 2006, 47, 12, 2357
dc.identifier.issn 0022-3530
dc.identifier.uri https://repository.geologyscience.ru/handle/123456789/43597
dc.description.abstract The garnet–muscovite (GM) geothermometer and the garnet–muscovite–plagioclase–quartz (GMPQ) geobarometer have been simultaneously calibrated under conditions of T = 450–760°C and P = 0·8–11·1?kbar, using a large number of metapelitic samples in the compositional ranges <f>${\hbox{ X }}_{\hbox{ Fe }}^{\hbox{ grt }}$</f> = 0·53–0·81, <f>${\hbox{ X }}_{\hbox{ Mg }}^{\hbox{ grt }}$</f> = 0·05–0·24, <f>${\hbox{ X }}_{\hbox{ Ca }}^{\hbox{ grt }}$</f> = 0·03–0·23 in garnet, <f>${\hbox{ X }}_{\hbox{ Ca }}^{\hbox{ pl }}$</f> = 0·17–0·74 in plagioclase, and Fe = 0·04–0·16, Mg = 0·04–0·13, AlVI = 1·74–1·96 in muscovite on the basis of 11 oxygens. The resulting GM thermometer yielded similar temperature estimates (mostly within ±50°C) to that of the garnet–biotite thermometer, and successfully discerned the expected systematic temperature change of prograde sequences, thermal contact zones and an inverted metamorphic zone. The resulting GMPQ barometer yielded similar pressure estimates (mostly within ±1·0?kbar) to the garnet–aluminum silicate–plagioclase–quartz (GASP) barometer and placed the aluminosilicate-bearing samples in the appropriate aluminosilicate stability fields. Application of the GMPQ barometer to thermal contact aureoles or rocks within limited geographical areas confirmed the expected constant pressures that should exist in these settings. The random errors of the GM thermometer and the GMPQ barometer are estimated to be ±16°C and ±1·5?kbar, respectively. When biotite or aluminosilicate is absent in metapelites, metamorphic P–T conditions may be determined by simultaneously applying the GM thermometer and the GMPQ barometer.
dc.title RECALIBRATION OF THE GARNET-MUSCOVITE (GM) GEOTHERMOMETER AND THE GARNET-MUSCOVITE-PLAGIOCLASE-QUARTZ (GMPQ) GEOBAROMETER FOR METAPELITIC ASSEMBLAGES
dc.type Статья


Files in this item

This item appears in the following Collection(s)

  • ELibrary
    Метаданные публикаций с сайта https://www.elibrary.ru

Show simple item record