IN SITU FTIR STUDY ON THE DEHYDRATION OF NATURAL GOETHITE
- DSpace Home
- →
- Геология России
- →
- ELibrary
- →
- View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.
dc.contributor.author | Prasad P.S.R. | |
dc.contributor.author | Shiva Prasad K. | |
dc.contributor.author | Babu E.V.S.S.K. | |
dc.contributor.author | Krishna Chaitanya V. | |
dc.contributor.author | Sreedhar B. | |
dc.contributor.author | Ramana Murthy S. | |
dc.date.accessioned | 2025-02-16T08:50:25Z | |
dc.date.available | 2025-02-16T08:50:25Z | |
dc.date.issued | 2006 | |
dc.identifier | https://www.elibrary.ru/item.asp?id=31390954 | |
dc.identifier.citation | Journal of Asian Earth Sciences, 2006, 27, 4, 503-511 | |
dc.identifier.issn | 1367-9120 | |
dc.identifier.uri | https://repository.geologyscience.ru/handle/123456789/47992 | |
dc.description.abstract | Fourier Transform Infrared (FTIR) spectroscopy, thermal analysis -Differential Scanning Calorimetry (DSC) and Thermo-Gravimetry (TG-DTG) were used to study the dehydration behavior of synthetic goethite and two naturally occurring goethite samples (Natural 1 and Natural 2) from Banded Iron Formation (BIF), at C.S. Halli, Chitradurg district, Karnataka, India. Goethites and its dehydration products were also identified by powder X-ray Diffraction (XRD) method. The dehydration temperatures were at 538, 567 and 578 K for synthetic, Natural 1 and 2 goethite, respectively. On approaching the dehydration temperature, infrared active modes of the hydroxyl groups have shown distinct variations. The peak position for the stretching mode around 3150 cm-1 was shifted upwards, while that for in-plane- deformation mode around 890 cm-1 was down shifted indicating weakening of strength of the hydrogen bonding. No intermediate phase, so called hydro-hematite, was observed in these studies. The total absorbance (area under the peak) of these modes have shown the Arrehenius type behavior in the temperature range 500-600 K, using which the activation energy for the dehydration process was estimated as 71, 103 and 85 kJ/mol for synthetic, Natural 1 and 2 goethites respectively. © 2005 Elsevier Ltd. All rights reserved. | |
dc.subject | DEHYDRATION | |
dc.subject | DSC | |
dc.subject | GOETHITE | |
dc.subject | HEMATITE | |
dc.subject | TG-DTG AND FTIR | |
dc.subject | XRD | |
dc.title | IN SITU FTIR STUDY ON THE DEHYDRATION OF NATURAL GOETHITE | |
dc.type | Статья | |
dc.identifier.doi | 10.1016/j.jseaes.2005.05.005 |
Files in this item
This item appears in the following Collection(s)
-
ELibrary
Метаданные публикаций с сайта https://www.elibrary.ru