INTERPRETATION OF A TWO-POINT FLUX STENCIL FOR SKEW PARALLELOGRAM GRIDS
| dc.contributor.author | Aavatsmark I. | |
| dc.date.accessioned | 2026-06-01T10:45:30Z | |
| dc.date.issued | 2007 | |
| dc.description.abstract | Control-volume formulations for elliptic equations often use two-point flux stencils, even for skew grids. Any two-point flux stencil may be interpreted as a multipoint flux stencil. This yields a definition of the permeability (or conductivity) tensor. Formulas for calculating the permeability tensor, based on the user-specified quantities in the two-point flux stencil, are given. Numerical test examples demonstrate the validity of the derivation. | |
| dc.identifier | https://elibrary.ru/item.asp?id=50936253 | |
| dc.identifier.citation | Computational Geosciences, 2007, 11, 3, 199-206 | |
| dc.identifier.doi | 10.1007/s10596-007-9042-1 | |
| dc.identifier.issn | 1420-0597 | |
| dc.identifier.uri | https://repository.geologyscience.ru/handle/123456789/53047 | |
| dc.subject | ANISOTROPY | |
| dc.subject | CONTROL-VOLUME DISCRETIZATION | |
| dc.subject | ERROR ANALYSIS | |
| dc.subject | PERMEABILITY TENSOR | |
| dc.subject | TWO-POINT FLUX | |
| dc.subject | 65N06 | |
| dc.subject | 76S05 | |
| dc.subject | 35R05 | |
| dc.title | INTERPRETATION OF A TWO-POINT FLUX STENCIL FOR SKEW PARALLELOGRAM GRIDS | |
| dc.type | Статья |